A directory of interpretations to the BACnet standard ASHRAE 135.
To download data sign in with GitHub
rows 10 / 114
doc_url | publish_date | id | summary |
---|---|---|---|
2004-06-26 00:00:00
|
135-2001-1
|
(Refers to the requirements presented in ANSI/ASHRAE Addendum b to ANSI/ASHRAE Standard 135-2001, Section 15.8 ReadRange Service.)
|
|
2004-06-26 00:00:00
|
135-2004-1
|
(Refers to the requirements presented in ANSI/ASHRAE Standard 135-2004, Section 16.1 DeviceCommunicationControl Service, specifically Section 16.1.2 (page 326), relating to the canceling of DeviceCommunicationControl disabling of communication via a ReinitializeDevice request.)
|
|
2004-06-26 00:00:00
|
135-2004-2
|
(Refers to the requirements presented in ANSI/ASHRAE Standard 135-2004, Section 13.11 GetEnrollmentSummary Service, specifically Section 13.11.1.2.1.4 (page 283), relating to the priority returned in a GetEnrollmentSummary response.)
|
|
2004-06-26 00:00:00
|
135-2004-3
|
(Refers to the requirements presented in ANSI/ASHRAE Standard 135-2004, Section 12.25.5, Log_Enable, and Section 12.25.12, Stop_When_Full.)
|
|
2004-06-26 00:00:00
|
135-2004-4
|
(Refers to the requirements presented in ANSI/ASHRAE Standard 135-2004, Sections 12.25.14, Log_Buffer, 12.25, and 15.7.2, Service Procedure.)
|
|
2004-06-26 00:00:00
|
135-2004-5
|
(Refers to the requirements presented in ANSI/ASHRAE Standard 135-2004, Section 12.25.5, Log_Enable, and Section 12.25.12, Stop_When_Full.)
|
|
2005-02-05 00:00:00
|
135-2004-6
|
(Refers to the requirements presented in ANSI/ASHRAE Standard 135-2004, Section 12.24.8, Exception_Schedule.)
|
|
2005-02-05 00:00:00
|
135-2004-7
|
(Refers to the requirements presented in ANSI/ASHRAE Standard 135-2004, Sections K.5.15 and K.5.16.)
|
|
2005-06-25 00:00:00
|
135-2004-8
|
(Refers to the requirements presented in ANSI/ASHRAE Standard 135-2004 in the following sections and tables relating to FLOATING_LIMIT and OUT_OF_RANGE transitions: Sections 12.2.19-12.2.21, Sections 12.3.20-12.3.22, Sections 12.4.16-12.4.18, Section 12.17.32, Sections 12.23.22-12.23.24, Section 13.3.5, Section 13.3.6, Table 13.2.)
|
|
2005-06-25 00:00:00
|
135-2004-9
|
(Refers to the requirements presented in ANSI/ASHRAE Standard 135-2004, Sections 12.1-12.4, 12.6-12.8, 12.15-12.20, 12.23, 12.25, and the corresponding tables in these sections, relating to intrinsic reporting.)
|